Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Front Bioeng Biotechnol ; 11: 1066391, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2299471

RESUMEN

Multisystem inflammatory syndrome in children (MIS-C) is a rare but serious condition that can develop 4-6 weeks after a school age child becomes infected by SARS-CoV-2. To date, in the United States more than 8,862 cases of MIS-C have been identified and 72 deaths have occurred. This syndrome typically affects children between the ages of 5-13; 57% are Hispanic/Latino/Black/non-Hispanic, 61% of patients are males and 100% have either tested positive for SARS-CoV-2 or had direct contact with someone with COVID-19. Unfortunately, diagnosis of MIS-C is difficult, and delayed diagnosis can lead to cardiogenic shock, intensive care admission, and prolonged hospitalization. There is no validated biomarker for the rapid diagnosis of MIS-C. In this study, we used Grating-coupled Fluorescence Plasmonic (GCFP) microarray technology to develop biomarker signatures in pediatric salvia and serum samples from patients with MIS-C in the United States and Colombia. GCFP measures antibody-antigen interactions at individual regions of interest (ROIs) on a gold-coated diffraction grating sensor chip in a sandwich immunoassay to generate a fluorescent signal based on analyte presence within a sample. Using a microarray printer, we designed a first-generation biosensor chip with the capability of capturing 33 different analytes from 80  µ L of sample (saliva or serum). Here, we show potential biomarker signatures in both saliva and serum samples in six patient cohorts. In saliva samples, we noted occasional analyte outliers on the chip within individual samples and were able to compare those samples to 16S RNA microbiome data. These comparisons indicate differences in relative abundance of oral pathogens within those patients. Microsphere Immunoassay (MIA) of immunoglobulin isotypes was also performed on serum samples and revealed MIS-C patients had several COVID antigen-specific immunoglobulins that were significantly higher than other cohorts, thus identifying potential new targets for the second-generation biosensor chip. MIA also identified additional biomarkers for our second-generation chip, verified biomarker signatures generated on the first-generation chip, and aided in second-generation chip optimization. Interestingly, MIS-C samples from the United States had a more diverse and robust signature than the Colombian samples, which was also illustrated in the MIA cytokine data. These observations identify new MIS-C biomarkers and biomarker signatures for each of the cohorts. Ultimately, these tools may represent a potential diagnostic tool for use in the rapid identification of MIS-C.

2.
Front Microbiol ; 13: 893801, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-1903084

RESUMEN

Background: There is an urgent need for harmonization between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology platforms and assays prior to defining appropriate correlates of protection and as well inform the development of new rapid diagnostic tests that can be used for serosurveillance as new variants of concern (VOC) emerge. We compared multiple SARS-CoV-2 serology reference materials to the WHO International Standard (WHO IS) to determine their utility as secondary standards, using an international network of laboratories with high-throughput quantitative serology assays. This enabled the comparison of quantitative results between multiple serology platforms. Methods: Between April and December 2020, 13 well-characterized and validated SARS-CoV-2 serology reference materials were recruited from six different providers to qualify as secondary standards to the WHO IS. All the samples were tested in parallel with the National Institute for Biological Standards and Control (NIBSC) 20/136 and parallel-line assays were used to calculate the relevant potency and binding antibody units. Results: All the samples saw varying levels of concordance between diagnostic methods at specific antigen-antibody combinations. Seven of the 12 candidate materials had high concordance for the spike-immunoglobulin G (IgG) analyte [percent coefficient of variation (%CV) between 5 and 44%]. Conclusion: Despite some concordance between laboratories, qualification of secondary materials to the WHO IS using arbitrary international units or binding antibody units per milliliter (BAU/ml) does not provide any benefit to the reference materials overall, due to the lack of consistent agreeable international unit (IU) or BAU/ml conversions between laboratories. Secondary standards should be qualified to well-characterized reference materials, such as the WHO IS, using serology assays that are similar to the ones used for the original characterization of the WHO IS.

3.
mSphere ; 7(4): e0019322, 2022 08 31.
Artículo en Inglés | MEDLINE | ID: covidwho-1891742

RESUMEN

In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies" (https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serological-sciences-network). SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology standard reference material and first WHO international standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. SeroNet institutions reported development of a total of 27 enzyme-linked immunosorbent assay (ELISA) methods, 13 multiplex assays, and 9 neutralization assays and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. In conclusion, SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons. IMPORTANCE SeroNet institutions have developed or implemented 61 diverse COVID-19 serological assays and are collaboratively working to harmonize these assays using reference materials to establish standardized reporting units. This will facilitate clinical interpretation of serology results and cross-comparison of research data.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , SARS-CoV-2 , Pruebas Serológicas/métodos
5.
Am J Trop Med Hyg ; 106(2): 562-565, 2022 01 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1614119

RESUMEN

The dried-tube specimen (DTS) procedure was used to develop the COVID-19 serology control panel (CSCP). The DTS offers the benefit of shipping materials without a cold chain, allowing for greater access without deterioration of material integrity. Samples in the panel were sourced from COVID-19 convalescent persons from March to May 2020. The immunoglobulin subtypes (total Ig, IgM, and IgG) and their respective reactivity to severe acute respiratory syndrome coronavirus 2 nucleocapsid, spike, and receptor-binding domain antigens of the samples were delineated and compared with the WHO International Standard to elucidate the exact binding antibody units of each CSCP sample and ensure the CSCP provides adequate reactivity for different types of serological test platforms. We distribute the CSCP as a kit with five coded tubes to laboratories around the world to be used to compare test kits for external quality assurance, for harmonizing laboratory testing, and for use as training materials for laboratory workers.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/inmunología , Manejo de Especímenes/métodos , Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/normas , Proteínas de la Nucleocápside de Coronavirus/inmunología , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Manejo de Especímenes/normas , Glicoproteína de la Espiga del Coronavirus/inmunología , Organización Mundial de la Salud
6.
Cell Rep Med ; 2(7): 100329, 2021 07 20.
Artículo en Inglés | MEDLINE | ID: covidwho-1272778

RESUMEN

Coronavirus disease 2019 (COVID-19) is associated with a wide spectrum of disease presentation, ranging from asymptomatic infection to acute respiratory distress syndrome (ARDS). Paradoxically, a direct relationship has been suggested between COVID-19 disease severity and the levels of circulating severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific antibodies, including virus-neutralizing titers. A serological analysis of 536 convalescent healthcare workers reveals that SARS-CoV-2-specific and virus-neutralizing antibody levels are elevated in individuals that experience severe disease. The severity-associated increase in SARS-CoV-2-specific antibody is dominated by immunoglobulin G (IgG), with an IgG subclass ratio skewed toward elevated receptor binding domain (RBD)- and S1-specific IgG3. In addition, individuals that experience severe disease show elevated SARS-CoV-2-specific antibody binding to the inflammatory receptor FcÉ£RIIIa. Based on these correlational studies, we propose that spike-specific IgG subclass utilization may contribute to COVID-19 disease severity through potent Fc-mediated effector functions. These results may have significant implications for SARS-CoV-2 vaccine design and convalescent plasma therapy.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/sangre , Inmunoglobulina G/sangre , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2/inmunología , Índice de Severidad de la Enfermedad
7.
Biosens Bioelectron ; 178: 113008, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1039297

RESUMEN

The association of mortality with the early humoral response to SARS-CoV-2 infection within the first few days after onset of symptoms (DAOS) has not been thoroughly investigated partly due to a lack of sufficiently sensitive antibody testing methods. Here we report two sensitive and automated testing-on-a-probe (TOP) biosensor assays for SARS-CoV-2 viral specific total antibodies (TAb) and surrogate neutralizing antibodies (SNAb), which are suitable for clinical use. The TOP assays employ an RBD-coated quartz probe using a Cy5-Streptavidin-polysacharide conjugate to improve sensitivity and minimize interference. Disposable cartridges containing pre-dispensed reagents require no liquid manipulation or fluidics during testing. The TOP-TAb assay exhibited higher sensitivity in the 0-7 DAOS window than a widely used FDA-EUA assay. The rapid and automated TOP-SNAb correlated well with two well-established SARS-CoV-2 virus neutralization tests. The clinical utility of the TOP assays was demonstrated by evaluating early antibody responses in 120 SARS-CoV-2 RT-PCR positive adult hospitalized patients. Higher TAb and SNAb positivity rates and more robust antibody responses at patient's initial hospital presentation were seen in inpatients who survived COVID-19 than those who died in the hospital. Survival analysis using the Cox Proportional Hazards Model showed that patients who had negative TAb and/or SNAb at initial hospital presentation were at a higher risk of in-hospital mortality. Furthermore, TAb and SNAb levels at presentation were inversely associated with SARS-CoV-2 viral load based on concurrent RT-PCR testing. Overall, the sensitive and automated TAb and SNAb assays allow the detection of early SARS-CoV-2 antibodies which associate with mortality.


Asunto(s)
Anticuerpos Antivirales/sangre , Técnicas Biosensibles/instrumentación , Prueba Serológica para COVID-19/instrumentación , COVID-19/inmunología , COVID-19/mortalidad , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Neutralizantes/sangre , Técnicas Biosensibles/estadística & datos numéricos , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Prueba Serológica para COVID-19/estadística & datos numéricos , Estudios de Cohortes , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Neutralización/estadística & datos numéricos , Ciudad de Nueva York/epidemiología , Pandemias , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Adulto Joven
8.
Diagn Microbiol Infect Dis ; 99(4): 115298, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-987459

RESUMEN

The novel coronavirus outbreak caused by the severe acute respiratory syndrome coronavirus (SARS-CoV-2) was first identified in December of 2019 in Wuhan, China. The local outbreak quickly rose to pandemic level that has spread to more than 188 countries with more than 19 million cases and 732,467 deaths worldwide. The current recommendation for testing is RT-PCR based tests of nasopharyngeal or alternatively nasal- and/or oropharyngeal swabs that detects infection with SARS-CoV-2 to diagnose acute infection. However, there is an urgent need for a quick and accurate antibody-based point-of-care test method to quickly identify evidence of SARS-CoV-2 infection among people who might be missed through active case finding and surveillance efforts. Serology tests measure the presence of antibodies in serum after infection. Here we compared the performance characteristics of 6 commercially available antibody-based point-of-care devices and their potential for identification of individuals infected at some time by SARS-CoV-2.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Humanos , Sistemas de Atención de Punto , SARS-CoV-2/inmunología , Sensibilidad y Especificidad
9.
Biosens Bioelectron ; 171: 112679, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: covidwho-983076

RESUMEN

The 2019 SARS CoV-2 (COVID-19) pandemic has illustrated the need for rapid and accurate diagnostic tests. In this work, a multiplexed grating-coupled fluorescent plasmonics (GC-FP) biosensor platform was used to rapidly and accurately measure antibodies against COVID-19 in human blood serum and dried blood spot samples. The GC-FP platform measures antibody-antigen binding interactions for multiple targets in a single sample, and has 100% selectivity and sensitivity (n = 23) when measuring serum IgG levels against three COVID-19 antigens (spike S1, spike S1S2, and the nucleocapsid protein). The GC-FP platform yielded a quantitative, linear response for serum samples diluted to as low as 1:1600 dilution. Test results were highly correlated with two commercial COVID-19 antibody tests, including an enzyme linked immunosorbent assay (ELISA) and a Luminex-based microsphere immunoassay. To demonstrate test efficacy with other sample matrices, dried blood spot samples (n = 63) were obtained and evaluated with GC-FP, yielding 100% selectivity and 86.7% sensitivity for diagnosing prior COVID-19 infection. The test was also evaluated for detection of multiple immunoglobulin isotypes, with successful detection of IgM, IgG and IgA antibody-antigen interactions. Last, a machine learning approach was developed to accurately score patient samples for prior COVID-19 infection, using antibody binding data for all three COVID-19 antigens used in the test.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/inmunología , Técnicas Biosensibles/instrumentación , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/sangre , Neumonía Viral/sangre , Anticuerpos Antivirales/inmunología , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/inmunología , Pruebas con Sangre Seca , Diseño de Equipo , Fluorescencia , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Dispositivos Laboratorio en un Chip , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/inmunología , SARS-CoV-2 , Sensibilidad y Especificidad
10.
J Infect Dis ; 223(1): 47-55, 2021 01 04.
Artículo en Inglés | MEDLINE | ID: covidwho-889569

RESUMEN

Passive transfer of antibodies from COVID-19 convalescent patients is being used as an experimental treatment for eligible patients with SARS-CoV-2 infections. The United States Food and Drug Administration's (FDA) guidelines for convalescent plasma initially recommended target antibody titers of 160. We evaluated SARS-CoV-2 neutralizing antibodies in sera from recovered COVID-19 patients using plaque reduction neutralization tests (PRNT) at moderate (PRNT50) and high (PRNT90) stringency thresholds. We found that neutralizing activity significantly increased with time post symptom onset (PSO), reaching a peak at 31-35 days PSO. At this point, the number of sera having neutralizing titers of at least 160 was approximately 93% (PRNT50) and approximately 54% (PRNT90). Sera with high SARS-CoV-2 antibody levels (>960 enzyme-linked immunosorbent assay titers) showed maximal activity, but not all high-titer sera contained neutralizing antibody at FDA recommended levels, particularly at high stringency. These results underscore the value of serum characterization for neutralization activity.


Asunto(s)
Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , COVID-19/terapia , Pruebas de Neutralización , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunización Pasiva , Sueroterapia para COVID-19
11.
AJP Rep ; 10(3): e270-e274, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: covidwho-804894

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-Cov-2) or coronavirus disease 2019 (COVID-19) is currently in worldwide pandemic state with very limited data about the mode of transmission to the growing fetus. There are a few published cases of COVID-19 infection in the infants born to COVID-19 positive mothers where most of the reported cases were either mildly symptomatic with positive COVID-19 polymerase chain reaction (PCR) or had negative COVID-19 PCR raising the question of vertical transmission. We present a case of likely intrauterine transmission of COVID-19 infection in a critically ill premature infant born to a COVID-19 infected mother and describing her clinical course thus far. The clinical presentation in the infant is consistent with COVID-19 infection described so far in literature along with positive PCR, and positive COVID-19 serology: immunoglobulin G, immunoglobulin M, and immunoglobulin A.

12.
Clin Chim Acta ; 509: 117-125, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: covidwho-526557

RESUMEN

BACKGROUND: In the ongoing COVID-19 pandemic, there is an urgent need for comprehensive performance evaluation and clinical utility assessment of serological assays to understand the immune response to SARS-CoV-2. METHODS: IgM/IgG and total antibodies against SARS-CoV-2 were measured by a cyclic enhanced fluorescence assay (CEFA) and a microsphere immunoassay (MIA), respectively. Independent performance evaluation included imprecision, reproducibility, specificity and cross-reactivity (CEFA n = 320, MIA n = 364). Clinical utility was evaluated by both methods in 87 patients at initial emergency department visit, 28 during subsequent hospitalizations (106 serial samples), and 145 convalescent patients. Totally 916 patients and 994 samples were evaluated. RESULTS: Agreement of CEFA and MIA was 90.4%-94.5% (Kappa: 0.81-0.89) in 302 samples. CEFA and MIA detected SARS-CoV-2 antibodies in 26.2% and 26.3%, respectively, of ED patients. Detection rates increased over time reaching 100% after 21 days post-symptom onset. Longitudinal antibody kinetic changes by CEFA and MIA measurements correlated well and exhibited three types of seroconversion. Convalescent sera showed a wide range of antibody levels. CONCLUSION: Rigorously validated CEFA and MIA assays are reliable for detecting antibodies to SARS-CoV-2 and show promising clinical utility when evaluating immune response in hospitalized and convalescent patients, but are not useful for early screening at patient's initial ED visit.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus , Técnicas de Laboratorio Clínico/tendencias , Infecciones por Coronavirus/sangre , Servicio de Urgencia en Hospital/tendencias , Hospitalización/tendencias , Neumonía Viral/sangre , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus/aislamiento & purificación , COVID-19 , Técnicas de Laboratorio Clínico/métodos , Estudios de Cohortes , Convalecencia , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/terapia , Femenino , Humanos , Inmunoensayo/métodos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/terapia , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA